Welcome to our websites!

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for Air Compressor Shut Off Switch, Normally Closed Pressure Switch, Ac Transducer Switch, If needed, welcome to help make speak to with us by our web page or cellular phone consultation, we are going to be delighted to serve you.
Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin Detail:

The pressure switch is mainly used in the refrigeration system, in the pipeline circulation system of high pressure and low pressure, to protect the abnormal high pressure of the system to prevent damage to the compressor.

DSC_0111
DSC_0106
DSC_0125
DSC_0108

After being filled, the refrigerant flows into the aluminum shell (that is, inside the switch) through the small hole under the aluminum shell. The inner cavity uses a rectangular ring and a diaphragm to separate the refrigerant from the electrical part and seal it at the same time.

When the pressure reaches the low-pressure switch-on value 0.225+0.025-0.03MPa, the low-pressure diaphragm (1 piece) is turned over, the diaphragm seat moves upward, and the diaphragm seat pushes the upper reed to move upward, and the contacts on the upper reed are on the bottom yellow plate. The contact of the compressor is contacted, that is, the low pressure is connected, and the compressor starts to run.

The pressure continues to rise. When it reaches the high-pressure disconnect value of 3.14±0.2 MPa, the high-pressure diaphragm (3 pieces) flips, pushing the ejector rod upwards, and the ejector rod rests on the lower reed, so that the lower reed moves upward, and the contact on the lower yellow plate The point is separated from the contact on the upper reed, that is, the high pressure is disconnected, and the compressor stops working.

The pressure gradually balances (ie decreases). When the pressure drops to the high-pressure switch-on value minus 0.6±0.2 MPa, the high-pressure diaphragm recovers, the ejector rod moves down, and the lower reed recovers. The contacts on the lower yellow plate and the contacts on the upper reed are restored. Point contact, that is, high pressure is connected, the compressor works.

When the pressure drops to the low-pressure cut-off value of 0.196±0.02 MPa, the low-pressure diaphragm recovers, the diaphragm seat moves down, the upper reed resets down, and the contact on the upper yellow leaf separates from the contact on the lower reed, that is, low-pressure disconnect , The compressor stops working.

In actual use, the switch is disconnected when there is no pressure. It is installed in the car air conditioner system. After the refrigerant is filled (usually 0.6-0.8MPa), the pressure switch is in the on state. If the refrigerant does not leak, The system works normally (1.2-1.8 MPa);The switch is always on.

when the temperature is above seven or eight degrees, When the system does not work normally, such as poor heat dissipation of the condenser or dirty/ice blockage of the system, and the system pressure exceeds 3.14±0.2 MPa, the switch will be turned off;If the refrigerant leaks or the temperature is below seven or eight degrees, and the system pressure is lower than 0.196±0.02 MPa, the switch will be turned off. In short, the switch protects the compressor.


4-30-73


4-30-7


4-30-77


4-30-75


4-30-71


4-30-76


Product detail pictures:

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures

Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin detail pictures


Related Product Guide:

We not only will try our greatest to present fantastic expert services to each purchaser, but also are ready to receive any suggestion offered by our prospects for Factory wholesale High Pressure Switch 410a - Pressure Switch For Refrigeration System – Anxin , The product will supply to all over the world, such as: Bolivia, Mauritania, Algeria, Our company is an international supplier on this kind of merchandise. We supply an amazing selection of high-quality merchandise. Our goal is to delight you with our distinctive collection of mindful items while providing value and excellent service. Our mission is simple: To supply the best items and service to our customers at the lowest prices possible.
  • High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Tony from Porto - 2018.06.18 17:25
    Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Agnes from Sweden - 2018.09.16 11:31
    Write your message here and send it to us
    WhatsApp Online Chat !